This is a working overview of REV-ERB agonist, written for readers who want more than a one-paragraph summary but less than a textbook.
This page was last updated on 2026-05-08 and is reviewed periodically as new material appears.
Detection of SR9009 in biological samples usually employs liquid chromatography coupled with tandem mass spectrometry. This method can identify the parent compound and sometimes metabolites in urine or blood. Because exposure can be low and clearance may be rapid, sample timing and limits of detection matter. Laboratories validate assays for sensitivity and specificity. Results are interpreted alongside chain-of-custody and quality-control records. Urine is the common matrix for anti-doping analysis, while blood may be used in research settings.
Handling recommendations for SR9009 in a laboratory setting include storing the solid at low temperature, protected from light and moisture. The compound is often dissolved in dimethyl sulfoxide or ethanol for experiments. Solutions should be prepared with appropriate personal protective equipment and disposed of according to local rules. Stability data for long-term storage are limited, so stock solutions are typically kept cold and used within defined periods. Records of preparation date and concentration support reproducibility.
SR9009 is not approved as a medicine by major regulatory agencies. It is commonly sold as a research chemical, a category that may fall outside customary drug approval and quality rules. In sports, the World Anti-Doping Agency lists SR9009 as a prohibited substance. Athletes who use it can face sanctions if it is detected in a sample. Legal status varies by country, and importation may be restricted. Enforcement practices differ across borders.
SR9009 is a synthetic small molecule studied as a REV-ERB agonist. REV-ERBα and REV-ERBβ are nuclear receptors that help regulate circadian rhythms and metabolic gene expression. The compound was identified in academic screening efforts to find synthetic ligands for these receptors. In cell and animal studies, SR9009 alters transcription of genes involved in lipid and glucose metabolism, and it can shift circadian behavior. It is not an approved therapeutic agent.
Mechanistically, SR9009 binds the ligand-binding domain of REV-ERBα/β and enhances recruitment of corepressor complexes. This represses target genes rather than activating them. Because REV-ERB proteins normally compete with ROR proteins at shared response elements, the net effect depends on tissue and timing. Researchers use SR9009 to probe how nuclear receptor signaling links the clock to metabolism, inflammation, and muscle biology. Findings are largely preclinical, and the precise contribution of each receptor subtype remains under study.
SR9009 is frequently discussed in fitness and research-chemical contexts, yet it has no approved medical indication. Regulatory agencies have not authorized it for human use, and it is not a standard prescription drug. Some sports organizations list it as a prohibited substance because of its potential performance-enhancing properties. Published human data are sparse, so claims about its effects in people often rely on animal models or anecdotal reports. Quality and identity of online materials can vary widely.
| Property | Value | Notes |
|---|---|---|
| Regulatory status | Not approved as a medicine in major jurisdictions | Sold as a research chemical; legal status varies |
| Anti-doping status | Prohibited by the World Anti-Doping Agency | Listed under non-approved substances or related category |
| Typical analytical method | LC-MS/MS | Used for detection and confirmation in biological samples |
| Storage temperature | −20 °C or lower for solid | Desiccated and protected from light |
| Common solution solvents | DMSO; ethanol | Aqueous solubility is limited |
Laboratory samples of SR9009 are typically supplied as a white to off-white powder. The compound dissolves readily in organic solvents such as dimethyl sulfoxide and ethanol, while its solubility in water is low. Because of this solubility profile, researchers often prepare concentrated stock solutions in an organic solvent before diluting them into aqueous assay buffers. Light exposure, moisture, and repeated freeze-thaw cycles can degrade many small molecules, so handling procedures usually aim to minimize these factors. Purity is commonly checked before use.
Storage conditions for research-grade SR9009 generally involve a freezer at approximately minus twenty degrees Celsius, sometimes lower for long-term preservation. Containers should remain tightly closed and protected from light. Desiccants may be used to limit moisture uptake. Solutions are often stored in aliquots to avoid repeated warming and cooling. Stability data for the compound under various conditions are limited, so laboratories typically follow supplier recommendations and verify performance through periodic analytical checks rather than assuming indefinite stability.
Identity and purity testing for SR9009 commonly uses liquid chromatography coupled with tandem mass spectrometry. This method separates the compound from matrix components and detects it by mass-to-charge transitions, providing sensitive and specific confirmation. Nuclear magnetic resonance spectroscopy can support structural identification, while high-performance liquid chromatography with ultraviolet detection may estimate purity. Because online products labeled as SR9009 may contain other substances or no active compound at all, independent verification is important in research settings. Certificates of analysis are useful but not a substitute for in-house testing.
Laboratory identification of SR9009 typically relies on chromatographic separation coupled to mass spectrometry, often with ultraviolet detection as a secondary check. Nuclear magnetic resonance spectroscopy can confirm molecular structure when a reference standard is available. Because many suppliers sell the compound as a research chemical, independent identity testing is important for experimental reproducibility. A single retention time is not sufficient proof of identity, especially when related compounds may be present. Purity assessments usually report a percentage based on area normalization.
SR9009 is generally described as poorly soluble in water and more soluble in organic solvents such as dimethyl sulfoxide and ethanol. Stock solutions are commonly prepared in an organic solvent before dilution into an aqueous buffer or vehicle. Precipitation can occur if the organic fraction is reduced too quickly or if the final concentration exceeds the compound's solubility limit. Sonication or gentle warming may aid dissolution in some protocols, but excessive heat can promote degradation. Container material and pH can also influence observed solubility.
SR9009 is a synthetic small molecule studied as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ. These receptors help regulate circadian rhythms, lipid metabolism, and inflammatory gene expression. In cell and animal experiments, SR9009 alters transcription of clock-controlled genes and metabolic pathways. The compound is not a hormone and does not resemble classical steroid structures. Its activity depends on binding to the ligand-binding domain of REV-ERB, where it can modify corepressor recruitment.
Research interest in SR9009 grew from studies of circadian biology and metabolic disease. Preclinical reports describe effects on exercise capacity, muscle metabolism, and blood lipid levels in rodents, but these findings come from controlled laboratory settings. The compound has low oral bioavailability in animals, which limits systemic exposure after swallowing. Investigators often use injected routes in experiments to achieve measurable plasma concentrations. Human clinical data are sparse, no approved therapeutic product exists, and whether animal effects translate to humans remains an open question.
In continuum mechanics, a branch of mathematics, the Burnett equations are a set of higher-order continuum equations for non-equilibrium flows and the transition regimes where the Navier–Stokes equations do not perform well. They were derived by the English mathematician D. Burnett.
== Media == Ariely has appeared in several documentary films and television productions. In 2011, he worked on the documentary The Flaw, which investigates the causes of the 2008 financial crisis. In it, Ariely explained and presented scientific data on the forces that shape human behavior, motivation, and decision-making. In 2015, Ariely appeared in another documentary, (Dis)Honesty: The Truth About Lies. It explores three key themes: why people lie, how often they do it, and the consequences of dishonest behavior. Ariely contributed to Boom Bust Boom, a 2015 documentary about economic crashes. In 2019, he appeared in The Inventor: Out for Blood in Silicon Valley, a documentary that tracks the rise and fall of Theranos. In 2022, he contributed to Why Like This? Lama Kacha, a Hebrew television series broadcast on Kan 11. In it, Ariely distilled complex scientific concepts and provided accessible explanations for the forces that shape human behavior, motivation, and decision-making. Ariely has also presented talks at several TED, with titles such as "Our Buggy Moral Code" and "Unraveling the Mysteries of Human Behavior".
== Products == Novo produces the drug semaglutide, used to treat diabetes under the brand names Ozempic and Rybelsus and obesity under the brand name Wegovy. Novo is also involved with hemostasis management, growth hormone therapy, and hormone replacement therapy. The company makes several drugs under various brand names, including Levemir, Tresiba, NovoLog, Novolin R, NovoSeven, NovoEight, and Victoza.
Sources: en.wikipedia.org
== Interactions == Anastrozole is thought to have clinically negligible inhibitory effects on the cytochrome P450 enzymes CYP1A2, CYP2A6, CYP2D6, CYP2C8, CYP2C9, and CYP2C19. As a result, it is thought that drug interactions of anastrozole with cytochrome P450 substrates are unlikely. No clinically significant drug interactions have been reported with anastrozole as of 2003. Anastrozole does not affect circulating levels of tamoxifen or its major metabolite N-desmethyltamoxifen. However, tamoxifen has been found to decrease steady-state area-under-the-curve levels of anastrozole by 27%. But estradiol levels were not significantly different in the group that received both anastrozole and tamoxifen compared to the anastrozole alone group, so the decrease in anastrozole levels is not thought to be clinically important.
Ovaleap was approved for medical use in the European Union in September 2013. It was approved for medical use in Australia in March 2021. Bemfola was approved for medical use in the European Union in March 2014.
holocentric (of a linear chromosome or chromosome fragment) Having no single centromere but rather multiple kinetochore assembly sites dispersed along the entire length of the chromosome. During cell division, the chromatids of holocentric chromosomes move apart in parallel and do not form the classical V-shaped structures typical of monocentric chromosomes.
Sources: en.wikipedia.org
Its legal status depends on the country and intended use. It is not an approved medicine in major jurisdictions. In sport, it is prohibited by anti-doping rules.
Laboratories typically use LC-MS/MS to detect SR9009 and related compounds in urine or blood. The method is sensitive but depends on sample collection timing. Confirmatory analysis follows quality-control procedures.
Solid material is generally kept cold, dry, and protected from light. Solutions are often stored in sealed containers at low temperature. Stability beyond recommended periods is not well documented.
SR9009 is a synthetic compound investigated as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ. It is used in preclinical research on circadian rhythm and metabolism. It is not an approved drug.