REV-ERB agonist is one of those subjects where the details matter more than the headlines. This page pulls together the background, the mechanisms, and the practical points readers ask about most.
Last reviewed on 2025-10-08. Where a claim depends on a specific study, the study is described rather than over-claimed.
In laboratory settings, SR9009 is commonly identified by its molecular structure and its interaction with REV-ERB receptors. Vendors may list it under synonyms such as Stenabolic or REV-ERB agonist, but those names do not define purity or identity. Analytical confirmation typically uses high-performance liquid chromatography with ultraviolet detection or liquid chromatography–mass spectrometry. A reference standard is needed to compare retention time and mass spectrum, because the compound can be confused with related research chemicals.
Handling practices for SR9009 focus on minimizing degradation and contamination. The solid is generally stored desiccated at or below -20 °C, protected from light and moisture. Stock solutions are often prepared in dimethyl sulfoxide or ethanol, then aliquoted to avoid repeated freeze–thaw cycles. Aqueous solubility is low, so formulations for animal studies may require cosolvents or suspending agents. Personnel should follow institutional chemical safety procedures, because toxicological data for humans are incomplete.
Identity and purity of SR9009 samples are usually checked with chromatographic and spectrometric methods. High-performance liquid chromatography can separate the compound from related impurities, while mass spectrometry provides molecular mass confirmation. Nuclear magnetic resonance spectroscopy may be used for structural verification in research settings. No single method proves biological activity, and certificates of analysis should be reviewed alongside raw data. Independent testing is often needed because online products vary widely.
SR9009 stability depends on temperature, moisture, light, and solvent. Solid material is generally kept cool and dry, while solutions may require protection from repeated warming and cooling. Degradation can appear as color changes, precipitate, or new chromatographic peaks. Researchers should follow supplier instructions and their own stability data. Long-term storage conditions for human use have not been established because the compound lacks approved clinical formulation.
SR9009 is supplied as a solid research chemical, often in milligram quantities. Laboratories typically weigh it in a controlled environment because fine powders can disperse. Stock solutions are commonly prepared in dimethyl sulfoxide and stored in small aliquots to reduce freeze-thaw cycles. Personal protective equipment and chemical fume hoods are standard when handling unknown or potent compounds. These practices address laboratory safety rather than human use.
| Property | Value | Notes |
|---|---|---|
| Appearance | White to off-white solid | Visual inspection is not sufficient for identity. |
| Solubility | Soluble in DMSO and ethanol | Low solubility in water. |
| Typical storage | -20 °C, desiccated, dark | Protect from repeated temperature changes. |
| Common analytical method | LC-MS or HPLC-UV | Reference standard required for comparison. |
| Common synonyms | SR9009; Stenabolic; REV-ERB agonist | Vendor naming may vary. |
SR9009 is a synthetic small molecule studied as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ. It is not an approved medicine and has no established human therapeutic use. The compound appears in scientific literature as a tool for probing circadian and metabolic regulation. Online sellers often label it as a research chemical, sometimes using the nickname Stenabolic. Its chemical identity is distinct from selective androgen receptor modulators, stimulants, and peroxisome proliferator-activated receptor delta agonists. Researchers use it mainly in cell and animal experiments.
At the molecular level, SR9009 binds REV-ERBα and REV-ERBβ and alters their repressive activity on target genes. These nuclear receptors help regulate the circadian clock, lipid synthesis, glucose metabolism, and inflammatory pathways. By changing transcription, the compound can shift the timing or magnitude of downstream metabolic processes in model systems. It does not act through androgen receptors or adenosine receptors, which distinguishes it from several substances sold for athletic performance. Whether the same transcriptional changes occur in humans at tolerable exposures remains an open question because controlled human studies are lacking.
Preclinical reports describe effects on exercise endurance, mitochondrial content, and lipid profiles in rodents, but these findings come from specific experimental conditions. Many studies use high doses or delivery methods that may not translate directly to human use. SR9009 has been reported to have low oral bioavailability and a short half-life, which complicates interpretation of oral dosing studies. It is not established as safe or effective for any indication. Literature discussions often separate its pharmacological mechanism from unverified claims made in fitness and supplement markets.
Regulatory agencies have not approved SR9009 for human therapeutic use. It is typically sold as a research chemical with labels stating that it is not for human consumption. The World Anti-Doping Agency prohibits the substance in sport, generally under the category of non-approved substances. Customs and national laws may restrict importation, sale, or possession. Product quality and legal status can vary by country and vendor, and therapeutic claims are not permitted in regulated advertising because the compound lacks approval.
Several misconceptions surround SR9009. It is often described as a SARM, a steroid, or an exercise pill, but its known target is the REV-ERB receptor family. Rodent studies have examined exercise capacity and metabolic markers, yet human outcomes remain unproven. Oral bioavailability appears low in animals, and human pharmacokinetics are not well characterized. Online products may contain impurities or different compounds, so identity and purity testing are important for research use.
Analytical chemists detect SR9009 with liquid chromatography-tandem mass spectrometry, commonly abbreviated LC-MS/MS. Sample preparation may involve protein precipitation, liquid-liquid extraction, or solid-phase extraction before analysis. Laboratories can target the parent compound or its metabolites, depending on the matrix and the purpose of testing. Anti-doping methods require sensitive and specific assays because concentrations in biological samples can be low. Reference standards and validated methods are essential for reliable identification and quantification.
SR9009 is a synthetic small molecule developed as a REV-ERB agonist. It binds to REV-ERBα and REV-ERBβ, nuclear receptors that help regulate circadian rhythms and metabolic gene expression. In cell and animal studies, the compound alters lipid and glucose handling and influences skeletal muscle oxidative capacity. Its exact effects in humans remain largely uncharacterized because controlled clinical trials have not been reported. The molecule is frequently described in preclinical literature as a metabolic modulator.
Research interest in SR9009 grew from studies showing improved running endurance in mice after short treatment periods. Those experiments linked the compound to increased mitochondrial content and fatty acid oxidation in muscle, but the findings come from animal models and specific dosing schedules. Independent replication has been limited, and the pathways connecting REV-ERB activation to exercise performance are still being mapped. Whether similar responses occur in humans is an open question.
SR9009 is often grouped with compounds studied for circadian and metabolic regulation rather than with classical anabolic steroids. Its interactions with nuclear receptors differ from those of androgen receptor ligands, and its proposed mechanisms involve transcriptional control rather than direct hormone signaling. Some sources classify it as a metabolic modulator because of observed effects on energy utilization. The distinction matters for regulation and for interpreting research results across different compound classes.
Laboratory samples of SR9009 are typically handled as research chemicals rather than pharmaceuticals. Suppliers usually state that the material is for research use only and not for human or veterinary administration. Storage recommendations generally call for a freezer at approximately −20 °C, protection from light, and a desiccated environment. The solid is often described as a white to off-white powder. Solubility is commonly reported in organic solvents such as dimethyl sulfoxide and ethanol, with low solubility in water.
Analytical identification and purity assessment often use high-performance liquid chromatography with ultraviolet detection or mass spectrometry. Liquid chromatography–tandem mass spectrometry is used to detect and quantify SR9009 in biological matrices, including urine and blood, for anti-doping or pharmacokinetic studies. Nuclear magnetic resonance spectroscopy can confirm molecular structure. Stability depends on form and storage: the solid is generally more stable than solutions, and repeated freeze–thaw cycles may degrade samples. Purity is typically reported as a percentage from a certificate of analysis.
Regulatory treatment of SR9009 varies by country and context. It is not approved as a therapeutic drug by agencies such as the United States Food and Drug Administration or the European Medicines Agency. Sports authorities list it as a prohibited substance; the World Anti-Doping Agency classifies it among hormone and metabolic modulators. Legal status for personal possession or sale differs across jurisdictions, and some countries may restrict it under analog or research chemical laws. Buyers who seek verified material often rely on independent laboratory testing because online product labels may not match contents.
=== Pregnancy and breastfeeding === Ixazomib and lenalidomide are teratogenic in animal studies. The latter is contraindicated in pregnant women, making this therapy regimen unsuitable for this group. It is not known whether ixazomib or its metabolites pass into the breast milk.
Binding of a ligand to a binding site on protein often triggers a change in conformation in the protein and results in altered cellular function. Hence binding site on protein are critical parts of signal transduction pathways. Types of ligands include neurotransmitters, toxins, neuropeptides, and steroid hormones. Binding sites incur functional changes in a number of contexts, including enzyme catalysis, molecular pathway signaling, homeostatic regulation, and physiological function. Electric charge, steric shape and geometry of the site selectively allow for highly specific ligands to bind, activating a particular cascade of cellular interactions the protein is responsible for.
Caesium-137 has a half-life of about 30.04 years, decaying by beta emission to stable barium-137. About 94.6% of the decays go to a metastable nuclear isomer of barium: barium-137m (137mBa) and the remainder directly to the ground state. Barium-137m has a half-life of about 153 seconds, its dropping to the ground state usually (85.1% of all 137Cs decays) emitting photons having energy 0.6617 MeV. This is responsible for all of the gamma ray emissions in samples of 137Cs.
18 October 2016: Astellas completes a clinical trial for Type-2 diabetes mellitus in Japan prior to October 2016 7 September 2016: Astellas Pharma plans a phase III trial for Type-1 diabetes mellitus (Combination therapy) in Japan 1 August 2016: Phase III clinical trials in type 1 diabetes mellitus (combination therapy) in Japan Ipragliflozin was also in development for type 2 diabetes mellitus in the U.S., Europe and other countries, and three phase II trials were completed in combination with metformin. This was since discontinued.
Sources: en.wikipedia.org
Medical applications of radio frequency (RF) energy, in the form of electromagnetic waves (radio waves) or electrical currents, have existed for over 125 years, and now include diathermy, hyperthermy treatment of cancer, electrosurgery scalpels used to cut and cauterize in operations, and radiofrequency ablation. Magnetic resonance imaging (MRI) uses radio frequency fields to generate images of the human body.
pyrimidine Abbreviated in shorthand with the letter Y. A single-ringed heterocyclic organic compound which, along with purine, is one of two molecules from which all nitrogenous bases (including the nucleobases used in DNA and RNA) are derived. Cytosine (C), thymine (T), and uracil (U) are classified as pyrimidines. The letter Y is sometimes used to indicate a generic pyrimidine; e.g. in a nucleotide sequence read, Y may be used to indicate that either pyrimidine nucleobase – C, T, or U – can be substituted at the indicated position.
Azvudine is an antiviral drug which acts as a reverse transcriptase inhibitor. It was discovered for the treatment of hepatitis C and has since been investigated for use against other viral diseases such as AIDS and COVID-19, for which it was granted conditional approval in China. Azvudine was first discovered in 2007. It costs 350 Chinese yuan per 7 days for COVID, as of November 2022.
Sources: en.wikipedia.org
Liquid chromatography–mass spectrometry is common for identity and purity checks. High-performance liquid chromatography with ultraviolet detection can also be used. Both methods require a suitable reference standard.
The solid is usually kept desiccated at -20 °C or lower and protected from light. Stock solutions are aliquoted to limit freeze–thaw cycles. Aqueous solutions are not generally recommended for long-term storage.
Laws differ by country and by intended use. It is not an approved medicine, and many vendors sell it as a research chemical. Purchasers are responsible for confirming local restrictions.
Laboratories commonly use liquid chromatography coupled with mass spectrometry to detect SR9009. The method can identify the compound and estimate concentration in a sample. Detection limits depend on the matrix and instrument.